HP Type Tungsten Carbide Burrs Rotary Bur Tool Dental Treatment Instruments 

HP Type Tungsten Carbide Burrs Rotary Bur Tool Dental Treatment Instruments 

    • HP Type Tungsten Carbide Burrs Rotary Bur Tool Dental Treatment Instruments 
    • HP Type Tungsten Carbide Burrs Rotary Bur Tool Dental Treatment Instruments 
    • HP Type Tungsten Carbide Burrs Rotary Bur Tool Dental Treatment Instruments 
    • HP Type Tungsten Carbide Burrs Rotary Bur Tool Dental Treatment Instruments 
  • HP Type Tungsten Carbide Burrs Rotary Bur Tool Dental Treatment Instruments 

    Product Details:

    Place of Origin: China
    Brand Name: D-Perfect
    Certification: CE/ISO/FDA/FSC
    Model Number: HP

    Payment & Shipping Terms:

    Minimum Order Quantity: negotiatable
    Price: negotiatable
    Packaging Details: 5 pcs/blister , single sizes 2000 packings per cartoon: 48cm*40cm*35cm
    Delivery Time: 25-30 working days after received the payment
    Payment Terms: T/T, MoneyGram, Western Union
    Supply Ability: 6,000 pcs / month
    Contact Now
    Detailed Product Description
    Product Name: Tungsten Carbide Burs Size: Round , Pear , Plame
    Standard: CE/ISO/FDA/FSC Application: Root Canal Treatment
    Material: Tungsten + Stainless Steel Packing: 5pcs/blister

    Tungsten Carbide Bur HP type US NO used for dental Stainless Steel Rotary use

     

    Specifications:

    US NO. 556 34
    557 35
    558 36
    560 1
    700 5

    701

    6
    702 7
    703 8

    Recommended speed

    200.000  rmp  
    Material Head Carbide YG8
    Handle Stainless Steel 420J2

     

    Description:

     

    Recommendations concerning the use of carbide burs

    1. Recommended speed

    The following speeds should not be exceeded for carbide burs:

    ISO Sizes: N° : 008-010 Rpm.: 400 000

    depending upon the size.

    One should avoid sudden changes of the speed as well as any jamming of the bur.

     

    2. Working pressure

    Do not operate the bur with a pressure of more than 100 gr. Excessive pressure may jam the bur or be the cause of a sudden change of the speed.

     

    3. Cleaning and sterilization

    Some liquids used for cleaning or disinfection may corrode the bur. Instruments can be desinfected by immersion in alcohol without dommage. The safest means still is a cleaning with plain water followed by hot air steriliz ation or auto-claving.

     

    4. Handpiece

    The concentricity of your handpiece or turbine should be checked periodically.

     

    5. We do not recommend the use of plasma sterilization

     

    Warning:

     

    1.Only skilled dentists are allowed to use.

    2. Be sure to sterilize this product for each use.

    3. Do not use this product except for the dental service and treatment. Use it in accordance with the intended use.

     

    Precautions for use

     

    1. To prevent infection, disinfect the product and ensure that sterilization is completed before use.
    2. Choose the most suitable type for each case and follow the general instructions.
    3. Before use, make sure that there is no deformation, scratches or cracks in the dental cavity.
    4. If the product's head is thin, long or large, there is a possibility of breaking or twisting. For this reason, it must be avoided
    Irrational point of view and excessive pressure.
    5. The above application is for dentists only.
    6. After use, dispose of as medical waste properly.
    7. Dispose of if product is damaged or contaminated.
    8. After use, wash away the attached body fluids and foreign body tissues with a medical cleaner and a brush.
    9. Carefully use this product to avoid stabbing your finger from the forefront he has.

     

     

    Storages and duration of use

    1. Avoid storing at high temperature, humidity and direct sunlight.

    Keep liquids away. Store it at room temperature.

    2. Do not damage or make a pinhole to packaging materials.

    3. Do not keep under germicidal lamp to avoid deterioration.

     

    Maintenances and inspections

    1. Sterilize this product by autoclave under established method and

    term for each use.

    Method of sterilization:

    Put this product in a sterilization pack or (or foil) and place it on a

    sterilization tray, or files stand for autoclave sterilization with

    reference to the following terms.

    Terms for sterilization:

    term(1) temperature: 121degrees Celsius time: 20 minutes or more

    term(2) temperature: 126degrees Celsius time: 15 minutes or more

    2. Do not use high pressure steam sterilizer which heats more than 200

    degrees Celsius including drying process.

    3. When reusing the instrument, wash away foreign substances

    completely and sterilize.

    4. Regarding use of medical cleaning agent, follow the instruction

    manual by its manufacturer strictly.

    5. Dispose the product if damaged or decreased in performance

     

    Packages

     

    FG 19 mm: blister 6 pcs. single sizes

    2000 Packings per cartoon: 48cm*40cm*35cm

     

     

     

    Applications:

    Dental Root Canal Treatment Hospital , Clinic , lab...

     

    Competitive Advantage:

    Imported raw material

    TÜV-certified Quality Management

    Recommend usage time : 10 tooth 

     

     